Technical Data
|
Technical Data |
Quick Cure |
Slow Rise |
|
Density (free rise) ASTM D-1622 |
28kg/m3 |
28kg/m3 |
|
Thermal Conductivity (k value) |
0.022 W/m.K |
0.024 W/m.K |
|
R-Factor |
6-7/inch |
6/inch |
|
Closed Cells ASTM D-2856 |
>90% |
92% |
|
Permeability (1" thick) |
3.5 perms |
3.5 perms |
|
Permeability (3.5" thick) |
<1 perm |
<1 perm |
|
Tack free/expansion time |
30 sec/60 sec |
60 sec/90 sec |
|
Cuttable |
3 min |
5 min |
|
Fire Rating DIN 4102-1 |
B2 |
B2 |
|
Tensile Strength ASTM D-1623 Parallel |
317 kPa |
268 kPa |
|
Compressive Strength ASTM D-1621 | ||
|
Parallel @ 10% |
158 kPa |
95 kPa |
|
Perpendicular @ 10% |
110 kPa |
101 kPa |
|
Shear Strength ASTM C-273 | ||
|
Parallel |
101 kPa |
141 kPa |
|
Perpendicular |
95 kPa |
128 kPa |
|
Dimensional Stability ASTM D-2126 | ||
|
Heat age (93 deg C) |
-0.6% |
+4.5% |
|
Humid age (70 deg C) |
+2.9% |
+1.0% |
|
Cold age (-40 deg C) |
-0.3% |
-0.3% |
|
Maximum U-Values (W/m2K)
|
2002
|
Foam depth mm
|
2007
|
Foam depth mm
|
|
Room in roof new build
|
0.2
|
115
|
0.16
|
130
|
|
Room in roof conversion
|
0.3
|
75
|
0.25
|
100
|
|
Pitched roof
|
0.16
|
85*
|
0.16
|
85*
|
|
Flat roof
|
0.25
|
85
|
0.16
|
135
|
|
Walls
|
0.35
|
60
|
0.25
|
75
|
|
Floors
|
0.25
|
50
|
0.22
|
60
|
|
Windows
|
2
|
n.a.
|
1.8
|
n.a.
|
|
Roof lights
|
2
|
n.a.
|
1.8
|
n.a.
|
Depth of 100mm